Hot

R290 intarCUBE

R290 chillers

Chillers in compact construction with glycol, water or brine and a low charge of R290.

Description

R290 intarCUBE chiller is a water or glycol chiller designed for commercial and industrial refrigeration applications, featuring a reduced R290 refrigerant charge.

CONSTRUCTION

  • Self-supporting casing made of galvanised sheet steel with weather-resistant polyester coating, with thermo-acoustic insulation in elastomeric foam.
  • Removable side panels around the entire perimeter.
  • Independent compressor compartment separated from the condensing air flow.
  • Sealed electrical panel, independent from the refrigerated compartment.
  • Flow and return pressure gauges and thermometers.

FANS

  • EC electronic fans with speed regulation by proportional control of the condensing pressure.
  • Fans with independent air flow rates.

REFRIGERATION CIRCUIT

  • Scroll or semi-hermetic compressors with capacity control, unloaded start and crankcase heater.
  • Refrigeration circuit made of annealed copper tubing with brazed joints, filter drier, ATEX high and low pressure switches, pressure transducers and temperature probes.
  • Stainless steel plate evaporator(s) brazed with pure copper and electronic expansion valve(s).
  • Economiser by means of an internal heat exchanger.

HYDRAULIC CIRCUIT

  • Hydraulic circuit made of copper tubing with threaded connections, with filling/drain valve, air vent, flow switch, and inlet and outlet thermometers and pressure gauges.
  • Flow switch.

SECURITY

  • ATEX fans for continuous ventilation of the refrigeration compartment.
  • Leak detector with audible and visual alarm.
  • Shunt trip coil for cutting off the power supply line to electrical components located in the refrigeration compartment.
  • Safety valve on the high- and low-pressure sides for common ducted discharge.

COIL

  • Copper microtube condenser coil with aluminium fins.

ELECTRICAL PANEL AND CONTROL

  • IntarChiller electronic controller with refrigeration control, condensing fan control with floating setpoint, pump control, etc.

CONSTRUCTION

  • Stainless steel screws.
  • Silentblocks for unit installation. (Accessory)

FANS

  • EC radial fans for air discharge to ambient.

REFRIGERATION CIRCUIT

  • Heat recovery (20 or 80 % of condenser heat) for hot water production (only without integrated hydraulic module).

HYDRAULIC CIRCUIT

  • Integrated hydraulic module with glycol circulating pump with stainless steel body and impeller, expansion vessel, safety valve, mesh filter, thermometers and pressure gauges, air vent and drain connection (except series 8 and units with heat recovery).
  • Standby pump.

COIL

  • Polyurethane-based anti-corrosion coating for the condenser coil.
  • Aqua Aero® anti-corrosion coating for copper microtube finned coil.
  • Anti-corrosion treatment on copper microtube and Alucoast® fin coil.

Intarcube R290 - INTARCON