{"id":78532,"date":"2020-01-28T10:00:04","date_gmt":"2020-01-28T09:00:04","guid":{"rendered":"https:\/\/www.intarcon.com\/instalar-co2-equipos-refrigeracion\/"},"modified":"2023-07-21T12:52:48","modified_gmt":"2023-07-21T10:52:48","slug":"inbetriebnahme-einer-co2-kuhlanlage","status":"publish","type":"post","link":"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/","title":{"rendered":"Inbetriebnahme einer CO2-K\u00fchlanlage"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"78532\" class=\"elementor elementor-78532 elementor-14375\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-52b3e838 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"52b3e838\" data-element_type=\"section\">\r\n\t\t\r\n\t\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\r\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6ce268\" data-id=\"6ce268\" data-element_type=\"column\">\r\n\t\t\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\r\n\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5b4b88d2 elementor-widget elementor-widget-text-editor\" data-id=\"5b4b88d2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>CO2-K\u00fchlanlagen erfordern<\/strong> eine vorherige Untersuchung und Planung, <strong>um das f\u00fcr den jeweiligen Fall am besten geeignete System bestimmen zu k\u00f6nnen.<\/strong><\/p><p>Die Verwendung dieses K\u00e4ltemittels hat zwei bekannte Phasen: <a href=\"https:\/\/www.intarcon.com\/en\/subcritical-co2-refrigeration\/\">unterkritisch<\/a> und <a href=\"https:\/\/www.intarcon.com\/en\/transcritical-co2-refrigeration\/\">transkritisch<\/a>. Unter anderem m\u00fcssen die Klimazone und die Anzahl der zu k\u00fchlenden Gegenst\u00e4nde ber\u00fccksichtigt werden.<\/p><h2>Die Vorteile und Anwendungen von CO2.<\/h2><p><b>Bevor wir uns mit den Empfehlungen f\u00fcr die Installation befassen, wollen wir einige der h\u00e4ufigsten Vorteile und Anwendungen in Erinnerung rufen, die <a href=\"https:\/\/www.intarcon.com\/de\/naturliche-ersatzkaltemittel\/\">CO2 als Ersatzk\u00e4ltemittel kennzeichnen.\u00a0<\/a><\/b><\/p><p>\u00a0<\/p><p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-78455\" src=\"https:\/\/www.intarcon.com\/wp-content\/uploads\/2023\/07\/beneficios-co2-de.webp\" alt=\"Vorteile der CO2-K\u00fchlung - INTARCON\" width=\"1354\" height=\"875\" srcset=\"https:\/\/www.intarcon.com\/wp-content\/uploads\/2023\/07\/beneficios-co2-de.webp 1354w, https:\/\/www.intarcon.com\/wp-content\/uploads\/2023\/07\/beneficios-co2-de-768x496.webp 768w, https:\/\/www.intarcon.com\/wp-content\/uploads\/2023\/07\/beneficios-co2-de-640x414.webp 640w, https:\/\/www.intarcon.com\/wp-content\/uploads\/2023\/07\/beneficios-co2-de-400x258.webp 400w, https:\/\/www.intarcon.com\/wp-content\/uploads\/2023\/07\/beneficios-co2-de-367x237.webp 367w, https:\/\/www.intarcon.com\/wp-content\/uploads\/2023\/07\/beneficios-co2-de-600x388.webp 600w\" sizes=\"(max-width: 1354px) 100vw, 1354px\" \/><\/p><h3>Vorteile der CO2-Verwendung.<\/h3><ul><li><strong>Es ist nat\u00fcrlich und schadstofffrei.<\/strong> Es sch\u00e4digt die Ozonschicht nicht und ist daher umweltfreundlicher und verringert die m\u00f6glichen Auswirkungen auf das Klima.<\/li><li><strong>Die Verwendung von CO2 ist wirtschaftlich und stabil<\/strong>, reduziert die Emissionen und wird zu einer sauberen Energiequelle, was es zu einer ziemlich sicheren und billigen Alternative f\u00fcr die K\u00fchlung macht.<\/li><li>Es<strong> ist sicher<\/strong>: ungiftig und nicht brennbar.<\/li><li><strong>Hohe Effizienz und Leistung.<\/strong><\/li><li>Hervorragende K\u00fchleigenschaften, die zu einem <strong>wesentlich geringeren Energieverbrauch f\u00fchren.<\/strong><\/li><li><strong>Hohe Dampfdichte.<\/strong><\/li><li><strong>Niedrige Viskosit\u00e4t:<\/strong> kleinere Rohre, wodurch die Kosten des Systems minimiert werden.<\/li><li>Anpassungsf\u00e4hig an Kaskadensysteme.<\/li><\/ul><h3>Die h\u00e4ufigsten Anwendungen von CO2<\/h3><ul><li style=\"font-weight: 400;\">Gewerbliche und industrielle K\u00e4ltetechnik.<\/li><li style=\"font-weight: 400;\">Transportk\u00fchlung.<\/li><li style=\"font-weight: 400;\">Kompakte Systeme.<\/li><li style=\"font-weight: 400;\">Superm\u00e4rkte.<\/li><li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Direkte, kaskadierte und indirekte Systeme.<\/span><\/li><\/ul><h2>\u00a0<\/h2><h2><b>Vorgehensweise bei der Inbetriebnahme einer CO2-Anlage.<\/b><b><\/b><\/h2><p><img decoding=\"async\" class=\"alignnone size-full wp-image-78480\" src=\"https:\/\/www.intarcon.com\/wp-content\/uploads\/2023\/07\/procedimiento-de-puesta-en-marcha-de-scaled.webp\" alt=\"Inbetriebnahmeverfahren f\u00fcr CO2-K\u00e4lteanlagen - INTARCON\" width=\"1024\" height=\"2560\" srcset=\"https:\/\/www.intarcon.com\/wp-content\/uploads\/2023\/07\/procedimiento-de-puesta-en-marcha-de-scaled.webp 1024w, https:\/\/www.intarcon.com\/wp-content\/uploads\/2023\/07\/procedimiento-de-puesta-en-marcha-de-768x1920.webp 768w, https:\/\/www.intarcon.com\/wp-content\/uploads\/2023\/07\/procedimiento-de-puesta-en-marcha-de-614x1536.webp 614w, https:\/\/www.intarcon.com\/wp-content\/uploads\/2023\/07\/procedimiento-de-puesta-en-marcha-de-819x2048.webp 819w, https:\/\/www.intarcon.com\/wp-content\/uploads\/2023\/07\/procedimiento-de-puesta-en-marcha-de-640x1600.webp 640w, https:\/\/www.intarcon.com\/wp-content\/uploads\/2023\/07\/procedimiento-de-puesta-en-marcha-de-400x1000.webp 400w, https:\/\/www.intarcon.com\/wp-content\/uploads\/2023\/07\/procedimiento-de-puesta-en-marcha-de-367x918.webp 367w, https:\/\/www.intarcon.com\/wp-content\/uploads\/2023\/07\/procedimiento-de-puesta-en-marcha-de-600x1500.webp 600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/p><p>\u00a0<\/p><p>F\u00fcr die Inbetriebnahme einer<strong> CO2-Anlage<\/strong> wird die folgende Vorgehensweise empfohlen:<\/p><ol><li style=\"font-weight: 400;\"><strong>Montage und Schwei\u00dfen aller Komponenten<\/strong>, mit Stickstoffstrom. Komponenten f\u00fcr CO2 zugelassen.<\/li><li style=\"font-weight: 400;\"><strong>Sichtpr\u00fcfung aller Rohre, Bauteile und Festziehen der Verbindungen.<\/strong><\/li><li style=\"font-weight: 400;\"><strong>Isolieren Sie Systemkomponenten,<\/strong> die dem Pr\u00fcfdruck nicht standhalten, und \u00f6ffnen Sie Ventile und Magnetventile, um alle Abschnitte des Kreislaufs auf gleichen Druck zu brin<\/li><li style=\"font-weight: 400;\"><strong>F\u00fchren Sie Dichtheits<\/strong>&#8211; und Widerstandspr\u00fcfungen des Systems gem\u00e4\u00df RSIF durch.<\/li><li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\"><strong>Machen Sie das System drucklos und schlie\u00dfen Sie die Vakuumpumpe<\/strong> an mindestens 3 Stellen des Kreislaufs an (MV-Saugung, LV-Saugung, Fl\u00fcssigkeit). Vorsicht mit den Ventilabdeckungen, sie k\u00f6nnen offen bleiben, wenn das System unter Vakuum steht. <\/span><\/li><li style=\"font-weight: 400;\"><strong>\u00d6lf\u00fcllung<\/strong> in Abscheidern.<\/li><li style=\"font-weight: 400;\">Vakuum unter 675 Pa absolut, f\u00fcr mindestens 2 Stunden. 270 Pa abs. wird empfohlen (wie bei HFC). Zus\u00e4tzliche Anforderungen gem\u00e4\u00df RSIF pr\u00fcfen.<\/li><li style=\"font-weight: 400;\"><strong>K\u00e4ltemittelbef\u00fcllung mit CO2-Gasflaschen<\/strong> bis zu 8 bar rel. in allen Anlagenteilen. Druckminderer verwenden. Vorsicht beim Anziehen der Muttern, da die Dichtungen w\u00e4hrend des F\u00fcllvorgangs beim Abk\u00fchlen undicht werden k\u00f6nnen.<\/li><li style=\"font-weight: 400;\"><strong>K\u00e4ltemittelbef\u00fcllung mit Sondenflasche (fl\u00fcssiges CO2)<\/strong>. Der Rest der F\u00fcllung ist abgeschlossen, bis das CO2 im Schauglas ist. Starten Sie 20% der Leistungen.<\/li><li style=\"font-weight: 400;\"><strong>Nach Erreichen stabiler Kondensationsbedingungen<\/strong> wird die erforderliche Leistung schrittweise erh\u00f6ht, bis 100 % der Anlage erreicht sind, wobei fl\u00fcssiges CO2 zugegeben wird, um die Last aller Verbraucher zu vervollst\u00e4ndigen. Wenn alle Verbraucher in Betrieb sind, sollte der CO2-Gehalt im Kessel auf dem unteren Niveau liegen.<\/li><\/ol><p><em><strong>Wichtig:<\/strong> Vermeiden Sie das Eindringen von fl\u00fcssigem CO2 in Messbr\u00fccken und Werkzeuge, die vor\u00fcbergehend an das System angeschlossen werden k\u00f6nnen.<\/em><\/p><p>\u00a0<\/p><h2>Zu ber\u00fccksichtigende Vorschriften f\u00fcr die Installation mit CO2<\/h2><p><strong>Auch f\u00fcr das Verfahren zur Inbetriebnahme einer CO2-Anlage gibt es eine Reihe von Vorschriften, die zu beachten sind.<\/strong><\/p><ul><li style=\"font-weight: 400;\">Verordnung (EG) Nr. 1005\/2009 des Europ\u00e4ischen Parlaments \u00fcber Stoffe, die zum Abbau der Ozonschicht f\u00fchren.<\/li><li style=\"font-weight: 400;\">K\u00f6niglicher Erlass 552\/2019 vom 27. September zur Verabschiedung der Sicherheitsvorschriften f\u00fcr K\u00e4lteanlagen und ihrer erg\u00e4nzenden technischen Anweisungen.<\/li><li style=\"font-weight: 400;\">K\u00f6niglicher Erlass 1042\/2013 vom 27. Dezember zur Genehmigung der Verordnung \u00fcber die Steuer auf fluorierte Treibhausgase. Gesetz 16\/2013.<\/li><li style=\"font-weight: 400;\">Gesetz 6\/2018, vom 3. Juli, \u00fcber den allgemeinen Staatshaushalt 2018. Artikel 85 (\u00c4nderung der vorherigen Verordnung).<\/li><li style=\"font-weight: 400;\">Verordnung (EU) Nr. 517\/2014 des Europ\u00e4ischen Parlaments und des Rates vom 16. April 2014 \u00fcber fluorierte Treibhausgase. &#8220;<a href=\"https:\/\/www.intarcon.com\/de\/f-gas-oder-das-f-gas-verbot\/\">F-Gas-Verordnung<\/a>&#8220;.<\/li><li style=\"font-weight: 400;\">K\u00f6niglicher Erlass 115\/2017 vom 17. Februar, der das Inverkehrbringen und die Handhabung von fluorierten Gasen und Ausr\u00fcstungen, die auf diesen basieren, sowie die Zertifizierung von Fachleuten, die diese verwenden, regelt und die technischen Anforderungen f\u00fcr Anlagen festlegt, die T\u00e4tigkeiten ausf\u00fchren, bei denen fluorierte Gase freigesetzt werden.<\/li><li style=\"font-weight: 400;\">Internationales Elektrotechnisches Komitee (IEC 60335-2-89). K\u00e4ltemittelf\u00fcllung in gek\u00fchlten M\u00f6beln.<\/li><\/ul><p><a href=\"https:\/\/www.intarcon.com\/de\/technische-beratung\/\"><img decoding=\"async\" class=\"alignnone size-full wp-image-68608\" src=\"https:\/\/www.intarcon.com\/wp-content\/uploads\/2022\/07\/CTA-Solicitar-Asesoria-DE.webp\" alt=\"Technische Beratung anfordern - INTARCON\" width=\"1191\" height=\"347\" srcset=\"https:\/\/www.intarcon.com\/wp-content\/uploads\/2022\/07\/CTA-Solicitar-Asesoria-DE.webp 1191w, https:\/\/www.intarcon.com\/wp-content\/uploads\/2022\/07\/CTA-Solicitar-Asesoria-DE-768x224.webp 768w, https:\/\/www.intarcon.com\/wp-content\/uploads\/2022\/07\/CTA-Solicitar-Asesoria-DE-640x186.webp 640w, https:\/\/www.intarcon.com\/wp-content\/uploads\/2022\/07\/CTA-Solicitar-Asesoria-DE-400x117.webp 400w, https:\/\/www.intarcon.com\/wp-content\/uploads\/2022\/07\/CTA-Solicitar-Asesoria-DE-367x107.webp 367w, https:\/\/www.intarcon.com\/wp-content\/uploads\/2022\/07\/CTA-Solicitar-Asesoria-DE-600x175.webp 600w\" sizes=\"(max-width: 1191px) 100vw, 1191px\" \/><\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\r\n\t\t\t\t<\/div>\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t<\/section>\r\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>CO2-K\u00fchlanlagen erfordern eine vorherige Untersuchung und Planung, um das f\u00fcr den jeweiligen Fall am besten geeignete System bestimmen zu k\u00f6nnen. Die Verwendung dieses K\u00e4ltemittels hat zwei bekannte Phasen: unterkritisch und transkritisch. Unter anderem m\u00fcssen die Klimazone und die Anzahl der zu k\u00fchlenden Gegenst\u00e4nde ber\u00fccksichtigt werden. Die Vorteile und Anwendungen von CO2. Bevor wir uns mit [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":14635,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[460],"tags":[],"class_list":["post-78532","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-installation-maintenance"],"featured_image_src":{"landsacpe":["https:\/\/www.intarcon.com\/wp-content\/uploads\/2020\/01\/Post_puesta_en_marcha_instalaci\u00f3n_CO2-1140x445.jpg",1140,445,true],"list":["https:\/\/www.intarcon.com\/wp-content\/uploads\/2020\/01\/Post_puesta_en_marcha_instalaci\u00f3n_CO2-463x348.jpg",463,348,true],"medium":["https:\/\/www.intarcon.com\/wp-content\/uploads\/2020\/01\/Post_puesta_en_marcha_instalaci\u00f3n_CO2-300x135.jpg",300,135,true],"full":["https:\/\/www.intarcon.com\/wp-content\/uploads\/2020\/01\/Post_puesta_en_marcha_instalaci\u00f3n_CO2.jpg",1181,531,false]},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Inbetriebnahme einer CO2-K\u00fchlanlage - INTARCON<\/title>\n<meta name=\"description\" content=\"Bei CO2-K\u00fchlanlagen sind eine Vorstudie und ein Entwurf erforderlich, um das spezifische System zu bestimmen.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Inbetriebnahme einer CO2-K\u00fchlanlage - INTARCON\" \/>\n<meta property=\"og:description\" content=\"Bei CO2-K\u00fchlanlagen sind eine Vorstudie und ein Entwurf erforderlich, um das spezifische System zu bestimmen.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/\" \/>\n<meta property=\"og:site_name\" content=\"INTARCON\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/intarcon\/\" \/>\n<meta property=\"article:published_time\" content=\"2020-01-28T09:00:04+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-07-21T10:52:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.intarcon.com\/wp-content\/uploads\/2020\/01\/Post_puesta_en_marcha_instalaci\u00f3n_CO2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1181\" \/>\n\t<meta property=\"og:image:height\" content=\"531\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"INTARCON\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Intarcon\" \/>\n<meta name=\"twitter:site\" content=\"@Intarcon\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"INTARCON\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/\",\"url\":\"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/\",\"name\":\"Inbetriebnahme einer CO2-K\u00fchlanlage - INTARCON\",\"isPartOf\":{\"@id\":\"https:\/\/www.intarcon.com\/de\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.intarcon.com\/wp-content\/uploads\/2020\/01\/Post_puesta_en_marcha_instalaci\u00f3n_CO2.jpg\",\"datePublished\":\"2020-01-28T09:00:04+00:00\",\"dateModified\":\"2023-07-21T10:52:48+00:00\",\"author\":{\"@id\":\"https:\/\/www.intarcon.com\/de\/#\/schema\/person\/3953ab26cc806bd58bd91f8a62054c03\"},\"description\":\"Bei CO2-K\u00fchlanlagen sind eine Vorstudie und ein Entwurf erforderlich, um das spezifische System zu bestimmen.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/#primaryimage\",\"url\":\"https:\/\/www.intarcon.com\/wp-content\/uploads\/2020\/01\/Post_puesta_en_marcha_instalaci\u00f3n_CO2.jpg\",\"contentUrl\":\"https:\/\/www.intarcon.com\/wp-content\/uploads\/2020\/01\/Post_puesta_en_marcha_instalaci\u00f3n_CO2.jpg\",\"width\":1181,\"height\":531},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\/\/www.intarcon.com\/de\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"K\u00fchlende Gase\",\"item\":\"https:\/\/www.intarcon.com\/de\/category\/kuhlende-gase\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Inbetriebnahme einer CO2-K\u00fchlanlage\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.intarcon.com\/de\/#website\",\"url\":\"https:\/\/www.intarcon.com\/de\/\",\"name\":\"INTARCON\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.intarcon.com\/de\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.intarcon.com\/de\/#\/schema\/person\/3953ab26cc806bd58bd91f8a62054c03\",\"name\":\"INTARCON\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/www.intarcon.com\/de\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/15e7dea3e8aff0fc73c1fbe5156ed313f6044f5727ad9a8c9752574cacdce03d?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/15e7dea3e8aff0fc73c1fbe5156ed313f6044f5727ad9a8c9752574cacdce03d?s=96&d=mm&r=g\",\"caption\":\"INTARCON\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Inbetriebnahme einer CO2-K\u00fchlanlage - INTARCON","description":"Bei CO2-K\u00fchlanlagen sind eine Vorstudie und ein Entwurf erforderlich, um das spezifische System zu bestimmen.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/","og_locale":"de_DE","og_type":"article","og_title":"Inbetriebnahme einer CO2-K\u00fchlanlage - INTARCON","og_description":"Bei CO2-K\u00fchlanlagen sind eine Vorstudie und ein Entwurf erforderlich, um das spezifische System zu bestimmen.","og_url":"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/","og_site_name":"INTARCON","article_publisher":"https:\/\/www.facebook.com\/intarcon\/","article_published_time":"2020-01-28T09:00:04+00:00","article_modified_time":"2023-07-21T10:52:48+00:00","og_image":[{"width":1181,"height":531,"url":"https:\/\/www.intarcon.com\/wp-content\/uploads\/2020\/01\/Post_puesta_en_marcha_instalaci\u00f3n_CO2.jpg","type":"image\/jpeg"}],"author":"INTARCON","twitter_card":"summary_large_image","twitter_creator":"@Intarcon","twitter_site":"@Intarcon","twitter_misc":{"Written by":"INTARCON","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/","url":"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/","name":"Inbetriebnahme einer CO2-K\u00fchlanlage - INTARCON","isPartOf":{"@id":"https:\/\/www.intarcon.com\/de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/#primaryimage"},"image":{"@id":"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/#primaryimage"},"thumbnailUrl":"https:\/\/www.intarcon.com\/wp-content\/uploads\/2020\/01\/Post_puesta_en_marcha_instalaci\u00f3n_CO2.jpg","datePublished":"2020-01-28T09:00:04+00:00","dateModified":"2023-07-21T10:52:48+00:00","author":{"@id":"https:\/\/www.intarcon.com\/de\/#\/schema\/person\/3953ab26cc806bd58bd91f8a62054c03"},"description":"Bei CO2-K\u00fchlanlagen sind eine Vorstudie und ein Entwurf erforderlich, um das spezifische System zu bestimmen.","breadcrumb":{"@id":"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/#primaryimage","url":"https:\/\/www.intarcon.com\/wp-content\/uploads\/2020\/01\/Post_puesta_en_marcha_instalaci\u00f3n_CO2.jpg","contentUrl":"https:\/\/www.intarcon.com\/wp-content\/uploads\/2020\/01\/Post_puesta_en_marcha_instalaci\u00f3n_CO2.jpg","width":1181,"height":531},{"@type":"BreadcrumbList","@id":"https:\/\/www.intarcon.com\/de\/inbetriebnahme-einer-co2-kuhlanlage\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/www.intarcon.com\/de\/"},{"@type":"ListItem","position":2,"name":"K\u00fchlende Gase","item":"https:\/\/www.intarcon.com\/de\/category\/kuhlende-gase\/"},{"@type":"ListItem","position":3,"name":"Inbetriebnahme einer CO2-K\u00fchlanlage"}]},{"@type":"WebSite","@id":"https:\/\/www.intarcon.com\/de\/#website","url":"https:\/\/www.intarcon.com\/de\/","name":"INTARCON","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.intarcon.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Person","@id":"https:\/\/www.intarcon.com\/de\/#\/schema\/person\/3953ab26cc806bd58bd91f8a62054c03","name":"INTARCON","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.intarcon.com\/de\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/15e7dea3e8aff0fc73c1fbe5156ed313f6044f5727ad9a8c9752574cacdce03d?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/15e7dea3e8aff0fc73c1fbe5156ed313f6044f5727ad9a8c9752574cacdce03d?s=96&d=mm&r=g","caption":"INTARCON"}}]}},"_links":{"self":[{"href":"https:\/\/www.intarcon.com\/de\/wp-json\/wp\/v2\/posts\/78532","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.intarcon.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.intarcon.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.intarcon.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.intarcon.com\/de\/wp-json\/wp\/v2\/comments?post=78532"}],"version-history":[{"count":0,"href":"https:\/\/www.intarcon.com\/de\/wp-json\/wp\/v2\/posts\/78532\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.intarcon.com\/de\/wp-json\/wp\/v2\/media\/14635"}],"wp:attachment":[{"href":"https:\/\/www.intarcon.com\/de\/wp-json\/wp\/v2\/media?parent=78532"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.intarcon.com\/de\/wp-json\/wp\/v2\/categories?post=78532"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.intarcon.com\/de\/wp-json\/wp\/v2\/tags?post=78532"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}